Hahn & Kolb
1 0 7 3 FOR MORE DETAI LS OR PRODUCTS , PLEASE VI S I T OUR ONL INE SHOP WWW.HAHN-KOLB.COM Temperature and ambient conditions monitoring \ Temperature and air-humidity measuring instruments Data logger with temperature probes Data logger for temperature and humidity Application: For environmental monitoring, e.g. during transpor- tation and storage Execution: Large display for current value indication and External temperature sensor connection Battery status indication User-friendly Windows software Hi-Lo visual and acoustic alarm Memory for up to 60,000 measured values with 3 variables Measuring interval adjustable from 1 second up to 24 hours High accuracy: ±0.5°C/± 3% Ident. No. 020: Additional measurement of relative air humidity and dew point Delivery: USB data cable, Windows software on CD and bat- tery (1x 3 V lithium type CR2032) Min./max. temperature measuring range -30 to 70 °C -30 to 70 °C Digit increment (meas- uring instrument for temperature) (°C) 0.1 0.1 Temperature error limit (residual area) (°C) 0.7 0.7 Min./max. humidity (rF) of measuring range - 0-99 % IP protection class IP 65 - 46200... Ident. No. 010 ● 020 ● Accessories for 46200 010 46200 020 46200... Temperature sensor, 40 x 3 mm, length 3 m Ident. No. 103 ● 103 ● 46200... Temperature sensor, 40 x 3 mm, length 8 m Ident. No. 108 ● 108 ● Prod. Gr. 456 Ident. No. 041 Ident. No. 021 infrared temperature measuring instruments Application: For measuring surface temperatures of rotating or live components Execution: Error limit ±2% or ± 2°C Ident. No. 021: HOLD/max./min./difference HI/LO limit value alarm Unit: Can be switched between °C/°F Display with backlight (optional activation) Adjustable emission degree 0.10 to 1.00 Dot laser (Class II) sighting aid (optional activation) Input for NiCr-Ni thermoelement sensor (type K) Ident. No. 041: HOLD/max./min./difference, additionally with AVG (average from measurement series) and lock (continuous measurement) HI/LO limit value alarm Unit: Can be switched between °C/°F Display with backlight (optional activation) Adjustable emission degree 0.10 to 1.01 Dot laser (Class II) sighting aid (optional activa- tion), with 2 laser beams to mark the measuring field size Input for NiCr-Ni thermoelement sensor (type K) Delivery: With battery in case. Min./max. temperature measuring range -60 to 500 °C -50 to 1000 °C Digit increment (measuring instrument for temperature) (°C) 0.1 0.1 Optical focus 11:1 50:1 Rechargeable battery/battery designation 1.5 V Mignon AA 9 V block 46135... Ident. No. 021 ● 041 ● Prod. Gr. 456
Made with FlippingBook
RkJQdWJsaXNoZXIy NzYwOTI=