Hahn & Kolb

1 0 8 2 ● = ON STOCK AT HEADQUARTERS ○ = NO STOCK I TEM Electric testing devices \ Multimeter/current clamps Ident. No. 320 BENNING CM 1-3 Ident. No. 310 BENNING CM 1-2 digital current clamp multimeters (EN standard 61010) for alternating and direct current Application: Ident. No. 300: For measurements in electrical installations. Ident. No. 310–320: For measurement in electrical installations. Execution: ƒ ƒ Ident. No. 320: ƒ ƒ Fork-shaped current clamp head (slimline design) ƒ ƒ Volt sensor Delivery: Ident. No. 310–320: Includes measuring leads Model CM 1-1 CM 1-2 CM 1-3 Display range 2000 digits 2000 digits 2000 digits Measuring accuracy +/- 2 % +/- 1 % +/- 1 % Min./max. test voltage (DC) - 0.1 V/AC-600 V/AC 0.1 mV/AC-1000 V/AC Min./max. test voltage (AC) - 0.1 V/AC-600 V/AC 0.1 mV/AC-750 V/AC Min./max. alternating current of measuring range 0.01 A-400 A 0.1 A-400 A 0.1 A-200 A Conductivity testing No Yes Yes Diode testing No No Yes Min./max. electrical-resistance measuring range - 0.1 Ohm-20 MOhm 0.1 Ohm-20 MOhm Max. collet opening (mm) 30 30 16 Memory function HOLD, MAX HOLD HOLD Measuring procedure RMS RMS RMS Overvoltage protection category CAT III/600 V CAT III/600 V CAT IV/600 V | CAT III/1000 V Length x width x height 180 x 70 x 42 mm 190 x 70 x 38 mm 190 x 60 x 40 mm 75024... Ident. No. 300 ● 310 ● 320 ● Prod. Gr. 751 Ident. No. 341 Ident. No. 330 BENNING CM 2 Digital current clamp multimeters With TRUE RMS current measurement Application: Ident. No. 330: For measurement in electrical installations/industry/PV. Ident. No. 341: For all demanding measuring tasks in industry and trade Execution: ƒ ƒ Ident. No. 330: Relative measurement (REL) ƒ ƒ Ident. No. 341: ƒ ƒ with logging function and Bluetooth interface ƒ ƒ Low-pass filter (HFR) for measurements of clocked motor drives ƒ ƒ Harmonics measurement (THD) to assess network quality ƒ ƒ Continuity (30 Ω - 100 Ω), diode (0.8 V) and two-pole rotary field test ƒ ƒ Auto sense function for automatic measurement range and function selection ƒ ƒ Integrated voltage sensor signals non-contact phase voltages and cable breaks in cables (red LED) Advantage: ƒ ƒ Ident. No. 341: ƒ ƒ Precise due to TRUE RMS AC, AC+DC measure- ment method ƒ ƒ Recording of load profiles on single and three- phase consumers in AC/DC networks ƒ ƒ Datalogger function LOG (10,000 measuring points, scanning frequency: 1 s - 10 min) Delivery: Ident. No. 330: Includes accessories such as bag, battery/batteries, measuring leads Ident. No. 341: Includes bag, batteries and meas- uring leads Notes: Ident. No. 341: Monitor, store and share your meas- urements for further evaluation via the free „BEN- NING MM-CM Link“ app within your organisation.

RkJQdWJsaXNoZXIy NzYwOTI=